If this menu is set to ‘1.Enable’, a checking is performed during the registration
process to determine whether a new fingerprint is already registered. This
prevents the same fingerprint from being registered again as a new user ID.
After selecting a setting value, press [ENT] button to continue setting.
3.8.4. Wiegand Output Setting
◆ At default screen [F2~] Æ [6.Device] Æ [4.Wiegand] ◆
<Wiegand Out>
0.None
1.26bit
2.34bit
3.Custom
Default setting: ‘0’
This function is used only in case that an additional controller operated by
Wiegand input is installed. After authentication is completed, the data in the
following types are sent to the Wiegand port of the terminal.
0.None
This is a general case and Wiegand out port is not used.
1.26bit
As “Sitecode[1byte] + User ID[2bytes]” is sent, the user ID is set
using less than 4 digits.
Transmission example) For SiteCode:045, UID:6543
Æ 1 00101101 0001 1001 10001111 0
2.34bit
As “Sitecode[1byte] + User ID[3bytes]” is sent, the user ID is set
using less than 7 digits.
However, if the user ID consists of 8 digits, Sitecode is ignored
and only “User ID[4bytes] is sent.
Transmission example) SiteCode:001, UID:123456
Æ 0 00000001 00000001 11100010 01000000 0
3.Custom As a setting made through user definition, this setting can be set
only at the server. You can only check it at the terminal.
※ It has nothing to do with the use of a Wiegand type card reader. If it is set to
‘1’ or ‘2’, the following site code value is set.
<Site Code>
(0-255):000
Default setting: ‘000’
This option can be used when the above Wiegand out is set to ‘1’ or ‘2’. Enter a
designated value between 0~255 in a site code to send to the Wiegand port
along with a user ID.